| Feature: |
| High resolution 12.1″color TFT display |
| Suitable for adult, pediatric and neonatal patient |
| Color TFT Screen, waveform up to 8 channels |
| Operation modes: Diagnostic, Monitor, Surgery |
| Light and portable with Built-in rechargeable lithium battery |
| UP to 10 kinds of monitor parameters |
| Arrhythmia analysis, pace-marker detection and S-T Segment analysis |
| 72 hour storage and review of trend grams and tables |
| 500 NIBP measurement date can be storage and recall |
| Electro surgical unit and defibrillation protected |
| Networkable with central monitoring system |
| Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate, Thermal Printer, CO2, IBP |
| ECG |
| 5-lead or 3-lead selectable |
| Input: 5-lead | :RA; LA; RL; LL; V or R; L; N; F; C |
| ECG waveforms of 7-leads display on the same screen |
| Lead selection | :I; II; III; avR; avL; avF; Vx |
| ECG waveform | :2 channels |
| Gain selection | :12.5mm/s, 25mm/s, 50mm/s |
| Accuracy | :±1bpm or ±1%, whichever is greater |
| Protection | :Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation |
| Calibration signal | :1mV±5% |
| Alarm range: Adult | :15-300bpm |
| Pediatric/Neonatal | :15-350bpm |
Arrhythmia analysis and S-T segment analysis
| Alarm range | :-2.0mV~2.0mV |
| S-T segment detection Measurement rang | :-0.2mv~2.0mv |
| Alarm | :Yes, audible and visual alarm, alarm events review |
NIBP
| Operation modes | :Manual/Automatic/STAT |
| Measurement unit | :mmHg/KPa selectable |
| Measurement types | :Systolic, Diastolic and Mean |
| Over-pressure protection | :YES |
| Resolution | :1mmHg |
| Accuracy | :Mean error and standard deviation per ANSI/AAMI SP-10 |
| Alarm | :Systolic, Diastolic, and Mean |
| Auto measure time | :Adjustable |
| Measurement rang | :10-270mmHg |
500 NIBP measurement date can be storage and recall
SpO2
| Measurement range | :0-100% |
| Accuracy | :70-100%, ±2% 0-69%, upspecified |
| Alarm range | :0-100% Pulse rate |
| Range | :20-254bpm |
| Accuracy | :±3bpm |
| Respiration |
| Method | :RA-LL impedance |
| Pediatric/Neonatal | :6-150rpm |
| Alarm range: Adult | :6-120rpm |
| Pediatric/Neonatal | :6-120rpm |
| Apnea alarm | :YES |
| Temperature |
| Channel | :Dual-channel |
| Alarm range | :0-50℃ |
| Apnea | :0.1℃ |
| CO2 |
| Method | :Thermo-dilution |
| Measurement range | :CO: 0.1-20 lit /min. |
| IBP |
| Channel | :2 channels |
| Pressure transducer | :Sensitivity: 5(mV/V/mmHg) |
| Transducer sites | :ART, PA, CVP, RAP, LAP, ICP |
| Alarm range | :-10~300mmHg |
| Standard Accessories: |
| ECG, SPO2, NIBP, 1- Skin TEMP |
| Optional Accessories: |
| IBP, CO2 |